P C McKenzie Company

Industrial Boiler and Natural Gas Compressor Sales

  • About
  • Blog
  • Contact Us

CALL US TODAY - 877-244-4883

  • Compressors
    • IR Compressor Packages
      • IR 05H25NGSX
      • IR 05H25NGDX
      • IR 20H40NGSX
      • IR 20H40NGDX
    • IR Compressor Parts
    • IR Bare Blocks
    • Small CNG Station for Fleet Vehicle Refueling
    • CNG Rental Units
      • Sauer Natural Gas Compressor
    • Natural Gas Compressor Valve Rebuild Program
    • CNG Relief Valve Recertification
    • Troubleshooting Guide
  • BOILERS
    • Boiler Service and Boiler Repair
    • Patterson Kelley Condensing Boilers
    • Patterson Kelley Non Condensing Boilers
    • Unilux Water Tube Boilers
    • Cast Iron Boilers
    • Boiler Burner Parts
      • Industrial Combustion Lo-Nox Burners
      • Gordon Piatt Burner Parts
      • Weishaupt Burner Parts
    • Hurst Boilers and Hurst Boiler Parts
    • Atlas Boiler
    • Ajax Boiler Gaskets and Ajax Boiler Parts
    • Venting Solutions
      • Engine Generator Turbine Exhaust
      • Zero Chase Grease Duct
      • Boiler Domestic Water Heater Venting
    • Draft Induction Fan
  • AXELSON
    • Axelson Relief Valves
      • Axelson Relief Valve Maintenance
      • How Does an Axelson Safety Valve Work?
      • Garrett Safety Relief Valves
      • Axelson Orifice
      • How to Test Relief Valves – Axelson Test Stand for Pilot Valves
    • Axelson Spare Parts
    • Axelson ESP Pilot Sensor
    • Axelson ESPHL – High/Low Pressure Controller
    • Axelson Sand Probe Valve with Sensor
    • Axelson CRBBM Relay
    • Axelson Actuator Pneumatic Diaphragm Actuator
    • Axelson PRV Relay
    • Axelson Differential Pressure Sensing Unit
  • OIL CONTROL
    • Oil Level Regulator
    • Murphy Oil Level Controller LM500
    • Oil Supply Tanks
    • Slow Flow Meter REN
    • Continuous Oil Change Module by Ren
    • Liquid Level Switch by Ren
  • Boiler Parts
    • Boiler Pumps
    • A & F Chemical Feed Pumps
    • A & F Chemical Feed Tanks
    • Everlasting Blowdown Valve
    • Kewanee
      • Kewanee Boiler Parts
      • Kewanee Vortex Damper Rebuild
      • Kewanee Boiler Gaskets
      • Kewanee Burner
      • Cam Assembly
      • Kewanee Burner Blower Wheel
    • Pressure Reducing Regulators
    • Boiler Gaskets
    • Flame Controls
    • Weishaupt
    • Gauge and Site Glass
  • AMOT
    • Amot Thermostatic Control Valves
    • 3-Way Control Valves
    • Diaphragm Operated Gas Valve
    • Air Intake Shut Off Valve
    • Bearing Temperature Detector
    • High Temperature Valve
    • Overspeed Sensing Valve
    • Master Safety Control
    • Metal Particle Detector
    • Amot Temperature Sensor
    • Amot Electric Trip Lever Switch
    • Amot G Valve – 3 Way Temperature Control Valve
  • RESOURCES
    • CNG Safety – Is Compressed Natural Gas Safe?
    • CNG
    • CNG Storage Cascades
    • NGV Fast Fill Station
    • NGV School Bus Refueling
    • NGV Service Tips
    • NG Compressor Troubleshooting
    • Boiler Service Tips
      • Boiler Questions About Your Boiler
      • Boiler Glossary
      • Boiler FAQ
  • Solar Power

Murphy Oil Level Controller LM500

murphy regulator

Murphy Oil Level Controller – Lube Level Maintainers –

Quality Oil Level Product – In Stock and Ready to Ship!

The Murphy LM500 oil level controller maintains oil level on any size engine. It also supports installations that require a three-wire, snap-action switch.

  • Test feature allows test of float and switch
  • Direct mount capable
  • Eliminates under/overfill due to human error
  • See oil level and condition without shutting down
  • Simple installation
  • Automatically maintains lube level
  • Positive sealing thumb valve
  • Not intended for use with fuel

Email us for Price:  slk@mckenziecorp.com

Murphy Oil Level Controller LM500

OVERVIEW

The LM500’s form C (three-wire) contact allows a controller/annunciator to be wired as a closed loop system, resulting in a reliable fault-sensitive circuit. Refer to LM500 Series Flow Rate Chart for application data.

The FW Murphy LM500-TF Oil Level Maintainer includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. The LM500 series maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running oil level, it will replenish oil as it is used. The low-level switch will alarm and/or shut down the equipment, if supply oil is lost and the equipment continues to use oil.

As crankcase oil level drops, the LM500 float also drops and opens the thumb valve. This allows oil to flow from the supply tank through the LM500 and into the crankcase. When proper level is achieved in the crankcase, the LM500 float rises causing the thumb valve to close off further oil flow.

The simple and unique thumb valve is non-clogging and provides a positive, leak-free seal.

If the clean oil supply is depleted and oil level continues to fall, the low-level switch will operate an alarm or equipment shutdown.

SPECIFICATIONS:

  • Crankcase Balance Vent Connection: 1/2 NPTF (top)
  • Inlet Connection: 1/2 NPTF removable screen (side)
  • Outlet Connection: One connected, two not used (plugged)
    2 x 3/4 NPTF (side)
    1 x 3/4 NPTF (bottom)
  • Thumb Valve Material: Viton
  • Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC
  • Wire leads: 18 AWG x 14 in. ± 2 in. (355 mm) length
  • Conduit Connection: 1/2 inch conduit (female, top)
  • Case: Die cast aluminum
  • Lens: Clear frog eye non-staining, high impact, high temperature polycarbonate; UV and heat stabilized
  • Dial: High visibility white background with solid green band for normal level indication
  • Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure)
  • Maximum Case Pressure: 15 psi (103 kPa)
  • Maximum Differential: 2 in. (51 mm) between running and stopped
  • Maximum Ambient Temperature: 250°F (121°C)
  • Float: 304 Stainless Steel
  • Flow Rates: Refer to LM500 Series Flow Rates chart for application data
  • Dimensions: Overall 6-9/16 inch tall x 6-3/16 inch wide x 3-1/2 inch deep
  • For exact dimensions, refer to document 00-02-0729 LM500 Installation Instructions
  • LM500/LM500-TF Shipping Dimensions: 9.5 (W) x 7.5 (D) x 11 in. (H) (241.3 (W) x 190 (D) x 279.4 mm (H))
  • LM500/LM500-TF Shipping Weight: 3 lbs. 7 oz (1.57 kg)

 

murphy regulator dimensions

murphy regulator dimensions

 

TYPICAL MOUNT:

Also – Check Out Our Oil Supply Tanks

 

murphy regulator mounting

 

Natural Gas for Our Future
Natural Gas an ideal fuel source for many reasons, including safety. Natural Gas is lighter than air. This means that it will not puddle (like gasoline) or sink to the ground like propane, which is heavier than air. Instead, Natural Gas will rise and dissipate in the atmosphere. Natural gas also has a higher ignition temperature. This means that it is much harder to ignite. Also the storage systems used for compressed natural gas are infinitely stronger that the gasoline tanks found on cars and trucks today.
Learn more >>

CONTACT US

Toll Free: 1-877-244-4883
Fax: 412-257-8890
Phone: 412-257-8866

SHIPPING ADDRESS
P.C. McKenzie Company
1365 McLaughlin Run Road
Pittsburgh, PA 15241

MAILING ADDRESS
P.C. McKenzie Company
P.O. Box 112638
Pittsburgh, PA 15241

- P.C. McKenzie Company is located South of Pittsburgh, Pennsylvania -

P. C. McKenzie Company

© Copyright 2025 PC McKenzie · All Rights Reserved ·