Hurst Boilers
Hurst Boiler has been manufacturing, designing, engineering and servicing gas, oil, coal, solid waste, wood, biomass and hybrid fuel fired steam and hot water boilers since 1967.
With installations across all industries worldwide, Hurst Boiler is recognized for the highest code standards, innovative engineering and design, Energy Star rating, and renewable, sustainable solutions for green building design and operational efficiency.
- Call Us First For All of Your Hurst Boiler Part Needs!
Hurst Boiler manufacturers a complete line of firetube, firebox, vertical tubeless and heat recovery boilers. If you are looking for a high-pressure boiler or a low-pressure boiler, please look through the Hurst product information and contact us with any questions.
Boilers range from 6hp to 2,000hp in both high and low pressure boiler designs. Steam and Hot Water for commercial and industrial applications.
HURST EURO SERIES
3-PASS FIRE TUBE DESIGN
Stress Relieving “Wetback” Construction for Extra-Long Life
100 – 2000 BHP
Steam 15-300 PSI
- Boiler is of the three-pass, scotch type, built and stamped in accordance with the requirements of the ASME Code, and listed by the National Board of Boilers and Pressure Vessel Inspectors
- Large combustion chamber with low heat release for complete combustion
- Smoke box is rear-mounted with slip-on stack connector
- Access to fireside is accomplished with hinged and davited front and rear doors. Flame observation ports are located on front and rear
- Openings for vessel cleanout and inspection of waterside are provided with 3” x 4” hand holes, and 12” x 16” manway access
- Insulated with 2” high density mineral wool, lagged with 22 gage grip jacketing, baked on finish to resist chipping and fading
- Firetubes are rolled and beaded on power boilers, expanded and flared on low pressure boilers
- Supports include lifting lugs securely welded to the top of shell; structural steel support legs on skids support the boiler so that special foundations are not required
- Wet Back Design Eliminates Refractory Rear Door & Baffles Between Flue Gas Passes
SERIES 45
3-PASS FIREBOX DESIGN (Low pressure)
Capacities from 8.5 to 813 BHP. 285 to 27215 MBTU/HR
- Thickest boiler steel in the industry
- Efficient 3-Pass Design
- Flexibility – Gas, Oil, Heavy Oil, and Combination Gas/Oil
- ASME Code Constructed & Stamped fro 15 PSI Steam30 Water
- Registered with the National Board of Boiler Inspectors
- Large Furnace Volume for Ultimate Combustion Efficiency
- Unified Refractory Base Floor
- Steel Skids and Lifting Eyes
- Low Heat Release Design
- Factory Insulated – 2″ Mineral Wool
- Factory Jacketed and Painted
- Easy Access to Fireside
- Ample Waterside Cleanout Openings
- Fully Automatic Operation
- U.L. Listed Controls & Trim
- Factory Test-fired
- Front & Rear Flame Observation Ports
SERIES 100
3-PASS FIREBOX DESIGN (Low pressure)
Capacities from 7.4 to 650 BHP. 248 to 21759 MBTU/HR
- Thickest boiler steel in the industry
- Efficient 3-Pass Design
- Flexibility – Gas, Oil, Heavy Oil, and Combination Gas/Oil
- ASME Code Constructed & Stamped for 15 PSI Steam/30 Water
- Registered with the National Board of Boiler Inspectors
- Competitively Priced, Easily Maintained, Designed for Efficiency
- Large Furnace Volume for Ultimate Combustion Efficiency
- Unified Refractory Base Floor
- Steel Skids and Lifting Eyes
- Low Heat Release – 5 Sq. Ft./HP
- Factory Insulated – 2″ Mineral Wool
- Factory Jacketed & Painted
- Easy Access to Fireside Surfaces
- Ample Waterside Cleanout Openings
- Fully Automatic Operation
- UL Listed, Forced Draft Burners
- Wet Back Construction
- UL Listed Controls & Trim
- Factory Test Fired
- Flame Observation Ports Front & Rear
SERIES 300
3-PASS DRY BACK DESIGN
Available in Steam or Hot Water Versions 15 – 800 Bhp Pressures to 300 psig
(15 to 300# steam, 30 to 160# hot water)
Also available in two pass design
Available with Low Nox
- Three Pass Design
- 81% Minimum Efficiency
- Davited Rear Door
- Low Maintenance
- 5 sq. ft. Heating Surface/HP
- Large Combustion Chamber with low heat release for complete combustion
- Rear Smoke Box includes slip-on stack connector and features hinged and davited rear door (40 HP & Larger) with 16″ dia. access door with 2″ observation port (80 Hp & larger)
SERIES 400
3-PASS WET BACK DESIGN
Capacities range from 15 to 2,000 HP and 1,004 to 50,213 MBTU/HR. Available for 15 PSI Steam and 30 PSI Water (60 PSI Water Optional).
- Factory assembled, prewired and tested
- No field assembly required
- UL listed boiler/burner packages
- Fully assembled, prepiped, prewired, pressure tested gas trains
- Complies with ASME, UL, CSD-1 and ASHRAE standards
- High efficiency, low stack temperatures
SERIES 500
4-PASS WET BACK DESIGN
- Factory assembled, prewired and tested
- No field assembly required
- UL listed boiler/burner packages
- Fully assembled, prepiped, prewired, pressure tested gas trains
- Complies with ASME, UL, CSD-1 and ASHRAE standards
- High efficiency, low stack temperatures
LPE SERIES
Modified Scotch Marine Boiler Designed to Fit Through a Standard 36″x80″ Door
- Modified Three Pass Scotch Design 20 to 100 HP, 670 to 3,348 MBTU/HR, 15# steam or 30# hot water. Through the door design. Also available with Low Nox
- Most heavily designed and built boiler in its class
- Welded Steel Firetube boiler, the LPE has extra-heavy 12-guage tubes for extended life. All tubes are attached to the tube sheets by rolling and flaring. There are no welded tubes in the LPE
- Thickest Materials used in the industry … Boiler Shell is 5/16″ thick boiler plate 20-40 HP. Twin boiler tube sheets are 1/2″ thick boiler plate. Insulation is 2″ mineral wool and is lagged with 22 gauge boiler jacket. Extra heavy 4″ channel iron boiler skids
4VT Cyclone Hot Water
Four-pass Vertical Tubeless Hot Water Boiler
- 6 to 125 HP, VT – Steam, 15 psi – 200 psi D.P.
- Compact space saving vertical design
- Shock Proof, no tubes to loosen
- Convenient access to “Eye High” burner
- Solid State controls for trouble free operation
- Factory assembled and fully automatic
- UL and ASME CSD – 1
- Simple and inexpensive to install
- Low Water Pressure Drips
- Standard Design pressure of 30 PSI optional to 160 PSI, 250 Degrees F
OXYMISER
Feedwater Deaerators
- Removes carbon dioxide as well as oxygen
- Raises the boiler feedwater temperature, eliminating thermal shock in boilers
- Improves overall boiler room efficiency
- Feedwater pumps are sized for each individual application – assuring total compatibility and optimum operation
- Vessels are ASME Code constructed for 50 psig
- Compact design means smaller boiler room requirements
- Integrated Monitoring and Control Systems are available for all Deaerator and Feedwater options